1 Scope
This part of IEC 61156 describes cables intended to be used for transmission of 1 Gbit/s over a single twisted
pair for office, home and industrial application. An example of an existing application
is 1000BASE-T1; see ISO/IEC TR 11801‑9906. The transmission characteristics of these cables are specified up to a frequency
of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to
be used for the work area wiring of shielded channels with a nominal length of 40 m.
Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF.
These cables can comprise more than one pair in case several systems are operated
in parallel. In this case, refer to Clause 7 of this document.
The cables covered by this document are intended to operate with voltages and currents
normally encountered in communication systems. While these cables are not intended
to be used in conjunction with low impedance sources, e.g. the electric power supplies
of public utility mains, they are intended to be used to support the delivery of low
voltage remote powering applications.
Annex A provides a blank detail specification (BDS) that can be used to summarize design
and performance requirements agreed upon between the supplier and the user of a specific
cable type.