1 Scope
This document specifies the geometry and method of use (installation and operating
conditions) of orifice plates when they are inserted in a conduit running full to
determine the flow rate of the fluid flowing in the conduit.
This document also provides background information for calculating the flow rate and
is applicable in conjunction with the requirements given in ISO 5167-1.
This document is applicable to primary devices having an orifice plate used with flange
pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as “vena contracta” and pipe tappings
are not covered by this document. This document is applicable only to a flow which
remains subsonic throughout the measuring section and where the fluid can be considered
as single phase. It is not applicable to the measurement of pulsating flow[1]. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more
than 1 000 mm, or for pipe Reynolds numbers below 5 000.