1 Scope
This document specifies a method for the determination of the dynamic viscosity of bituminous binders by means of a vacuum capillary viscometer at 60 °C in a range
between 0,003 6 Pa⋅s and 580 000 Pa⋅s. Other temperatures are possible if calibration
constants are known. Bituminous emulsions and non-newtonian binders (e.g. some polymer
modified bitumen) are not within the scope of this method.
WARNING — The use of this document can involve hazardous materials, operations and equipment.
This document does not purport to address all of the safety problems associated with
its use. It is the responsibility of the user of this document to identify the hazards
and assess the risks involved in performing this test method and to implement sufficient
control measures to protect individual operators (and the environment). This includes
appropriate safety and health practices and determination of the applicability of